Guides · Gate motors
How to set gate motor limits: ET, Centurion, Gemini and garage motors
A gate motor's limits are the open and closed positions it stops at. Get them wrong and the gate stops short, bangs into its post or runs off the end of its track. Every make sets them differently: some learn them with a single routine, some use magnets or blocks on the rack, some push against fixed stoppers. Here's how limits work, the outline for each common motor from its maker's manual, and what has to be right before you start.
Six-month guarantee on our repairs

What limits are, and why they drift
A sliding gate motor knows where it is in one of three ways:
- A marker on the gate: Centurion's D-series use an origin magnet fixed to the gate and count the motor's turns from it.
- A block on the rack and a switch in the motor: ET's Drive motors use a limit actuator on the rack that the motor senses at the closed end, then measure the rest.
- Solid stoppers: Gemini's DC sliders run gently into end stoppers and learn where they are.
Limits drift when something moves: a car bumps the gate, the rack slips or a section is replaced, the marker or actuator is knocked or works loose, or the gate is lifted back onto its track after jumping off. They also have to be reset after a new control card or a factory reset.

Before you set anything
Every manual starts with the same groundwork, and skipping it is why a setup fails:
- The gate must run freely by hand. The motor learns how hard the gate is to push during setup and uses that to detect obstructions. A dragging gate gives it the wrong idea, and setup either fails or the gate reverses later.
- The marker, actuator or stoppers must be fitted and tight.
- The gate starts about halfway, released, moved by hand and then re-engaged, so it can run either way safely.
- Keep everyone clear. During setup the gate runs with its obstruction sensing not yet learnt.
- The battery must be charged. A weak battery gives a false reading of the gate's effort.
ET Drive motors: run-time setup
ET's Drive 300, Drive 500 and 600 and Drive 1000 all learn their limits in one routine called run-time setup:
- With the limit actuator fitted on the rack and the gate halfway, hold the enter key on the card until it beeps twice.
- Choose run-time setup and confirm the gate is halfway.
- Tell it which way the gate closes. It creeps closed until it senses the actuator.
- It starts opening: press enter where you want it to stop, fine-tune, and confirm.
- It closes slowly to check the distance, warns you, then runs fully open and closed at full speed to learn the gate's profile.
Messages that mean it didn't work: e-l (the closed limit wasn't seen), and on a Drive 1000, Learn Error with a reason such as Limit Range, Manual Released or Gate Too Long. Model-by-model detail is on the ET Drive 500 and 600, Drive 300 and Drive 1000 pages.
Centurion D-series: the limits wizard
On a Centurion D5-Evo, the limits are set through the setup wizard on the card's display:
- Check the origin marker is correctly fitted on the gate.
- Put the motor on manual, move the gate halfway, and re-engage it.
- On a new controller, choose the operating profile when asked (ZA for South Africa).
- The controller goes into the limits setup: follow the steps on the screen as the gate runs to learn its closed and open positions.
Later, holding the oblong enter key for two seconds opens the setup menu if the limits need redoing. When the limits won't set, the usual reason is the origin marker: the motor can't see it, it's loose, or it's in the wrong place. On a D10, Centurion's fault table calls this No magnet detected. Full detail is on the D5-Evo manual and the D10 faults page.
Gemini sliders: learning the stoppers
Gemini's DC sliders have no limits to adjust. They learn from two solid end stoppers, which Gemini makes compulsory:
- With mains and battery connected, release the motor, move the gate halfway and re-engage it.
- Press the test button on the card or a remote. The gate closes slowly to the closing stopper.
- Press again. It opens slowly to the opening stopper, and both ends are learnt.
If the first press opens the gate instead of closing it, the motor direction is set the wrong way, which is a single DIP switch on the card. If a stopper is moved later, the motor must learn again from scratch. More on the Gemini manuals page.
Swing gates
Swing gate motors are set differently from sliders: most have mechanical end stops on the arm, and the control box learns the travel between them. On ET's Wingo, for example, the stoppers on each arm are set first, then a run-time setup checks each motor's direction and learns both gates' travel. Move a stopper afterwards and the setup must be redone. See the ET Wingo manual.
When to leave it to us
Setting limits involves opening the motor's cover, near its mains and battery connections, and running a gate with its safety sensing not yet learnt. If you're not comfortable with that, or the setup keeps failing, leave it to us. Call us when:
- the setup fails more than once with the gate running freely;
- the marker, actuator or rack has been damaged;
- the gate has been off its track or the rack has moved;
- you don't have the manual for your motor, or it's an older or less common make.
We set limits as part of most gate repairs, test the obstruction sensing afterwards, and every repair carries our six-month guarantee on our repairs. No call-out fee when we do the work. If no work is done, a R650 call-out fee applies.
Questions
Questions about setting gate limits
How do I set the limits on my Centurion D5 Evo?
With the origin marker fitted, put the motor on manual, move the gate halfway and re-engage it; the setup wizard on the display then takes you through the limits as the gate learns its closed and open positions. Holding enter for two seconds reopens setup later. See the Centurion steps.
My Centurion D5 Evo gate isn't setting the limits. What can I do to fix this?
Check the origin marker is fitted, tight and in the right place, that the gate runs freely by hand and that the battery is charged, then start again with the gate halfway. If it still fails, the marker or sensor needs a technician. See the groundwork.
How to set ET gate motor limits?
Use run-time setup: with the limit actuator on the rack and the gate halfway, hold enter until two beeps, choose run-time setup, set the closing direction, stop it at the open point and let it profile the gate. See the ET steps.
How do I program the limits on my DTS gate motor?
We hold no DTS manual, so we don't publish its steps; the limits are set on site by a technician, who then tests that the gate stops and reverses safely. Book us.
How do I set the limits on my garage door opener?
It depends on the make: Hydro Doors' Digi One and Digi 6 use SET with UP and DOWN to set open and closed positions, the Digi 7 does the same from its menu, and the Digidoor III learns its own limits after one press of Enter. See the Digidoor manual.