Skip to content

24/7 emergency repairs across Gauteng

081 566 5451

Electric fences · Bedfordview

Electric fence repairs in Bedfordview, and Nemtek's Druid energisers

A Druid in Essexwold showing a spanner, a siren in Oriel that sounded, stopped, and now stays quiet, a fence in Morninghill that alarms whenever the neighbour's does: we repair and install electric fences across Bedfordview. 2-year warranty and a compliance certificate on every new electric fence we install.

Our promise

2-year warranty and a compliance certificate on every new electric fence we install

Our promise

Six-month guarantee on our repairs

Bedfordview

Bedfordview and the areas around it. Every area we cover

Nemtek's Druid 13 and 15 LCD

The Druid 13 and 15 LCD are Nemtek's single-zone energisers for a house's wall-top fence. They run from a 12 V 7 Ah battery that the mains keeps charged, and Nemtek puts a new, fully charged battery at typically more than 24 hours of back-up, less on a fence in poor condition. Their settings survive even if the battery runs completely flat in a long outage. Nemtek recommends running them from a remote keypad, which unlocks most of their features; a Nemtek tag or a remote switch also works.

What each symbol on the display means is on electric fence repairs in Edenvale. This page is about what sits behind them, from the installer's side of the manual.

A technician shining a torch on the terminals of an open electric fence energiser box in a garage

The spanner, and the letter behind it

A spanner on a Druid's display means it needs a service. With the front cover off, the energiser shows a letter that narrows down the cause:

Druid 13 and 15 LCD service letters, from Nemtek's installer manual
LetterCause
AThe auxiliary fuse has blown
BThe battery fuse has blown, or the battery is faulty or disconnected
IInterference on the fence has been detected
NIt has lost contact with a slave energiser
S, F or VA fault in the high-voltage circuit or its sensing

The cover is for a technician to open, because the mains comes into the box. Three fast-blow fuses sit inside, and each gives itself away. With the 4 A main fuse gone, the display shows a battery symbol instead of the mains plug. With the 2 A battery fuse gone, the energiser stops the moment the mains does. With the 2 A auxiliary fuse gone, the siren and strobe fall silent. A fuse blows for a reason, so we find the reason before fitting a new one.

Why the siren stops, and when it comes back

A fence siren isn't meant to sound forever, and a Druid is set up to stop it. Out of the box:

  • It sounds for 2 minutes, then is held off for 3 minutes before it can sound again. An installer can set the sounding time anywhere from 10 seconds to 4 minutes 10 seconds.
  • After 3 alarms that nobody has reset, a re-arm time takes over, a whole day by default, so the siren doesn't go off again and again while you're away. Nemtek notes that the law requires this.

So a siren that has gone quiet while the fence is still faulty hasn't fixed itself. The fault is still there; the timer is just keeping the street quiet. Reset it at the keypad, and if it alarms again, book a technician.

When a fence counts as low

A Druid doesn't wait for a dead fence before it complains. It drives the fence and reads the voltage that comes back from the far end, against levels the installer sets. The factory settings, from Nemtek's manual:

  • 9.0 kV out, in high power, adjustable from 6.0 to 9.2 kV.
  • CHECK when the returning voltage falls below 4.0 kV: something is loading the fence, such as plants, a cracked insulator or a wire on a bracket.
  • BAD, and the alarm, at or below 3.0 kV.
  • 3 bad pulses before it alarms, adjustable from 1 to 15, so a single blip doesn't set it off.
  • 1.5 kV in low power, for when the fence is turned down.

The levels can be changed, but lowering an alarm level to stop false alarms only hides the fault that's causing them. We find and fix the fault instead.

Shared walls and the neighbour's fence

Bedfordview's stands share their boundary walls, and sometimes a wall carries two electric fences, one on each side, from two energisers. If the wires come into contact, or someone tries to defeat the fence's alarm detection, a Druid can raise a fence interference alarm, shown as the letter I behind the spanner. Nemtek enables it on some models and not others, so an installer checks the setting. Two fences on one wall have to be kept apart, or separated by a barrier, as the electric fence standard requires, and we work out which wires belong to which energiser before touching either.

What a careful installation looks like

Nemtek's installation notes read like a checklist of the faults we're called out to fix later. On the fences we put up:

  • High-voltage cable runs from the energiser to the fence, earth included, and never shares a conduit or a hole with the keypad, gate or mains wiring.
  • Joints in the fence wire are made with ferrules or line clamps, never twisted, and without mixing metals such as copper on steel.
  • Three earth spikes go in close to the energiser.
  • Gate switch and keypad cables stay within 100 m, and don't run alongside the fence wires. Each energiser takes at most two keypads.
  • An alarm panel or radio transmitter is linked through an isolation relay, and never powered from the energiser's battery.
  • The fence is tested with a short and a break at points along its length, in the Druid's test mode, which is switched off again afterwards.
A technician on a ladder holding a fence tester against the strands of an electric fence on a boundary wall

Electric fence repairs across Bedfordview

We repair Nemtek's Druid, Wizord and Merlin energisers and keypads, JVA's Z-series, and the fences themselves: broken wires, cracked insulators, loose brackets, earth spikes damaged by paving or digging, gate switches, sirens and strobes. All our spare parts are genuine, and every repair comes with our six-month guarantee on our repairs. The checks that are safe to try first, without touching the wires, are in the fault finder below.

New fences and certificates

A new fence starts with a walk along the walls with you, to agree the lines, the zones and where the energiser, keypad and earth spikes go, and to see where it meets a neighbour's fence or the gate. It's built to the rules Nemtek and JVA print in their manuals, tested, and handed over with its certificate. Certified electric fence installer. If you're selling and only need the certificate, see electric fence certificates.

Typical electric fence prices

Market prices in Gauteng, from cost guides and shop listings, not ours:

  • Energiser repair: R800–R2 500 (Kandua)
  • Simple repairs (insulators, a broken wire) including call-out: R700–R1 400 (Kandua)
  • Nemtek Druid 13 LCD, in shops: about R2 940–R3 280 (Takealot, NeonSales)
  • Nemtek Druid 15 LCD, in shops: about R2 740–R3 540 (Takealot, NeonSales)
  • 12 V 7 Ah battery, in shops: R230–R450 (Takealot)

Prices checked October 2026. Your exact price is set in a free quote before any work starts. No call-out fee when we do the work. If no work is done, a R650 call-out fee applies.

Booking a fence technician in Bedfordview

On the job card, give the energiser's make and model if you can see it, what the display or keypad shows, and what the fence is doing. Our fence technicians cover all of Bedfordview: Essexwold and Oriel, Senderwood and Morninghill, St Andrews and Bedford Park, Bedford Gardens, Dowerglen and Malvern East. Same-day repairs are offered when the day allows, and a fence that's down at night is treated as urgent.

Fault finder

What is your fence doing?

Pick what you're seeing for the likely causes, the safe checks you can do yourself, and when to stop and book. Taken from the manufacturers' own manuals.

What's it doing?

Likely causes

Electric fence · the alarm keeps going off

Most likely first

  1. The fence voltage has dropped below the alarm level: something is touching the wires, or plants have grown into the fence.

  2. The gate input is open: the gate isn't fully closed.

  3. The fence condition is poor: dirty or failed insulators, or wet insulators after rain.

Safe checks you can do

When to stop and book

Never touch the fence wires or open the energiser. If the alarm won't clear, we'll find the fault on the fence.

Questions

Electric fence questions in Bedfordview

What does the spanner on my Nemtek Druid mean?

The energiser needs a service. With the cover off, a letter shows the cause, from a blown fuse or battery fault to interference or a high-voltage fault, so it's a job for a technician. Read about the spanner.

Why did my electric fence siren stop sounding?

By design: a Druid sounds for 2 minutes, holds off for 3, and after 3 alarms nobody has reset, waits a day before re-arming. The fault may still be there. Read about the siren.

Why does my Druid work on mains but stop in a power cut?

Often the battery or its 2 A fuse. With the battery fuse blown, the energiser stops the moment the mains goes off. Read about the fuses.

At what voltage does a Nemtek Druid alarm?

By default it shows CHECK below 4.0 kV and alarms at or below 3.0 kV returning from the fence, after 3 bad pulses. Read about the levels.

Book a technician

Get an electric fence quote in Bedfordview

Job card

We WhatsApp or call you back. Fields marked (required) are needed.

Property type
When
Photos (optional, up to 4)

No call-out fee when we do the work. If no work is done, a R650 call-out fee applies.