Manual · Nemtek Druid
Nemtek Druid manual: keypad codes, display symbols and settings
Nemtek's Druid energizers are the LCD-screen units on a great many Gauteng electric fences: the single-zone Druid 13, 15 and 18, the bigger 114, and the two-zone Druid 25 and 28. They're best run from a keypad in the house, and almost everything an owner needs is a short code ending in the hash key. Here's what the screen is telling you, what each user code does and how the two-zone models differ, from Nemtek's own manuals.
2-year warranty and a compliance certificate on every new electric fence we install

The Druid range
- Druid 13 LCD and Druid 15 LCD: single-zone energizers with an LCD screen, running from the mains with a 12 V, 7 Ah rechargeable lead-acid battery inside. Nemtek says a new, fully charged battery typically gives more than 24 hours of backup, less on a fence in poor condition.
- Druid 18 and Druid 114: larger single-zone units, with a relay output (OUT1) that can be switched from the keypad.
- Druid 25 and Druid 28: the "2x" range, with two independent outputs, so the fence can be run as two zones. A Druid 4-Zone keypad can control up to four zones on two energizers.
Every Druid keeps its settings through a total power loss, even if the battery runs completely flat in a long outage. Nemtek's own feature is its arc-avoiding regulation: when wet, dirty or salty insulators start to arc, the Druid runs the fence just below the voltage where arcing starts, rather than pushing all its energy through the leak, which keeps the fence stronger.

The screen's colours and symbols
The Druid LCD's backlight tells you its state from across the yard:
| Colour | Meaning |
|---|---|
| Blue | The energizer is off |
| Green | All is well |
| Yellow | An alarm has happened in the past, or another medium-priority event |
| Red | An alarm is happening now |
The symbols on the screen link to labels printed above it, so the same letter can mean different things depending on where it sits. The ones owners see most: o under the fence label means the fence is off, but on the right under the gate label it means the gate is open; lo means low power; ! means the fence voltage is below the check level and x below the alarm level; t means the cover is or was opened; s means silent alarm; and a digit from 0 to 9 shows the fence's condition, the higher the better. A mains symbol shows mains present, mains failed in the past, or mains off with the battery good, low or flat.
Keeping the fence condition high
The Druid's fence condition reading, and its GOOD, CHECK and BAD display, drop as the fence leaks power. The check and alarm levels are set by the installer. Nemtek's advice for keeping the reading up is plain maintenance:
- cut back plants and remove any growth touching the wires;
- clear dead slugs, snails, spiders and insects off the insulators;
- replace insulators that have cracked or failed.
A reading that keeps falling after rain usually points to wet foliage or tired insulators somewhere along the line. If it stays low with the fence clean, the earth system or a hidden break is next, which is our job.
Using a Druid without a keypad
Unless the installer has disabled it, a Druid can be switched with Nemtek's plastic tab held over the matching logo on the front:
- On or off: hold the tab there until a short beep, then take it away. The energizer changes state.
- Silence an alarm: hold the tab there past the first short beep until a second, longer beep. The siren (if it hasn't timed out), the beeper and the strobe stop.
- Clear an alarm from memory: an alarm-history symbol means the fault has gone; switching off and on, or holding the tab to the long beep, clears it. An alarm symbol that stays means the fault is still there and must be fixed first.
Some installers wire a remote switch instead of using the tab.
Druid keypad codes
With a keypad, there are two users: a master user, who can switch the fence and change settings and PINs, and a reset user, who can only silence and clear alarms. Every code ends with #. Leave more than five seconds between keys and the keypad beeps fast and forgets what you typed; a code it accepts gets two beeps. Your installer should have changed both PINs from the factory ones when the fence was handed over.
| What you want | What to enter |
|---|---|
| Switch the fence on or off | Master PIN, # |
| Silence and clear an alarm | Reset PIN, # |
| Bypass the fence alarm / undo | Master PIN, \* 2 1 # / \* 2 0 # |
| Low power / full power | Master PIN, \* 3 1 # / \* 3 0 # |
| Bypass the gate alarm / undo | Master PIN, \* 4 1 # / \* 4 0 # |
| Gate chime on / off | Master PIN, \* 5 1 # / \* 5 0 # |
| Gate alarm instant / delayed | Master PIN, \* 7 1 # / \* 7 0 # |
| Silent alarm on / off | Master PIN, \* 8 1 # / \* 8 0 # |
| Bypass the service alarm / undo | Master PIN, \* \* 1 # / \* \* 0 # |
| Panic alarm | 9 1 # (no PIN) |
| Change a PIN | Master PIN, \* 0, then 1 (master) or 2 (reset), #; new PIN, #; new PIN again, # |
Low power is meant for times like children playing near the fence: the voltage drops to a level the installer chose, far less painful to touch. Silent alarm stops the siren and strobe but keeps the internal beeper, which is handy when testing.
Reading the fence from the keypad
The display information codes need no PIN, because they change nothing:
- 6 0 #: back to the normal GOOD, CHECK or BAD display.
- 6 1 #: the peak voltage going out and coming back, in kilovolts.
- 6 2 #: the energy stored, in joules, and how hard the energizer is working, as a percentage. It can't work harder than 100%.
- 6 3 #: how much voltage is lost along the fence, as a percentage.
- 6 4 #: the internal battery voltage.
The out-and-return reading is the most useful: a big gap between them, or a return far lower than the output, means power is leaking somewhere along the fence. Holding 1 or 7 on the keypad makes its symbols brighter or dimmer.
Druid 25 and 28: two zones, one keypad
The Druid 25 and 28 run two separate outputs, so a break on the back wall doesn't hide what's happening at the front. Because one keypad serves both zones, Nemtek gives it a way to focus on one: on a Druid 4-Zone keypad, one ZONE label is lit at a time, and whatever you enter goes to that zone and the energizer that runs it. The SELECT label moves the focus. With the energizers grouped, one 4-Zone keypad can control up to four zones on two energizers.
The user codes are the same as on the single-zone Druids; they simply act on the zone in focus.
Service alarms and when to call us
A service warning can show briefly after a long mains failure while the battery recovers. If it stays, Nemtek says the battery may need replacing or something else in the energizer or fence needs attention; if your installer stored their number in the energizer, it shows on the display during a service condition.
Call us when the fence condition stays low after you've cleared the line, the battery symbol stays low or flat after a day on mains, the tamper symbol appears and you didn't open the cover, or the display shows red with no obvious cause. Don't open the energizer: it stores a dangerous charge. We repair Druid energizers, replace batteries, earth systems and insulators, and fit keypads. All our spare parts are genuine, and every repair carries our six-month guarantee on our repairs. New fences are built by certified electric fence installer.
Druid prices, and Nemtek's PDFs
In South African shops:
- Nemtek Druid 15 LCD: about R2 740–R3 540 (Takealot, NeonSales)
- Nemtek Druid 18: about R4 490 (Takealot)
- Nemtek Druid 25 LCD (2 zone): about R6 230 (NeonSales)
- Nemtek Druid 28 LCD: about R5 190–R5 210 (Takealot, NeonSales)
- Nemtek Druid 114 LCD (14 J): about R8 250 (NeonSales)
These are the market's figures, not ours. Prices checked October 2026. Your exact price is set in a free quote before any work starts. No call-out fee when we do the work. If no work is done, a R650 call-out fee applies.
The official PDFs, from Nemtek:
- Nemtek Druid LCD user manual and Nemtek Druid 13/15/18 LCD energizer, installer manual
- Nemtek Druid 25 and 28 user manual and Nemtek Druid 25/28 LCD energizer, installer manual
The Merlin keypad has its own page, and more on the brand is on Nemtek.
Questions
Nemtek Druid questions
What does a red screen mean on a Nemtek Druid?
Red means an alarm is happening now; yellow means one happened earlier, green that all is well and blue that the energizer is off. Check the symbols to see whether it's the fence, the gate or the power. See the colours.
How do I put a Nemtek Druid on low power?
Enter your master PIN, then * 3 1 #; * 3 0 # puts it back to full power. The low-power voltage is set by your installer. See the keypad codes.
How do I silence a Nemtek Druid alarm?
Enter the reset PIN and #, or hold the Nemtek tab over the logo until the second, longer beep. If the alarm symbol stays, the fault is still on the fence. See using the tab.
How long does a Druid battery last in a power cut?
Nemtek says a new, fully charged 12 V 7 Ah battery typically gives more than 24 hours, less on a fence in poor condition; an older battery gives far less. See the Druid range.
Book a technician
Get an electric fence quote
Job card
We WhatsApp or call you back. Fields marked (required) are needed.