Electric fences · Midrand
Electric fence installation and repairs in Midrand
A new fence for a house in Noordwyk, a business park in Randjespark that needs four zones to alarm as one system, a JVA energiser in Vorna Valley that gives up early in load-shedding: we install and repair electric fences across Midrand. 2-year warranty and a compliance certificate on every new electric fence we install.
2-year warranty and a compliance certificate on every new electric fence we install
Six-month guarantee on our repairs
Midrand and the areas around it. Every area we cover
Installing a fence, from survey to certificate
- The walk. Along the whole boundary with you: walls, palisade, gates, trees, the neighbours' fences, and where the energiser, keypad, siren and earth spikes will go.
- The design. How many lines, how many zones and how big an energiser. A zone is a length of fence the energiser watches on its own, so an alarm tells you which part of the boundary it came from.
- Brackets and wire. Brackets fixed to the wall or fence, insulators on each, and the lines strung and tensioned.
- Gates. Contacts so an open gate is noticed, and gates arranged so they open without anyone touching a live line.
- Warning signs on every gate and spaced no more than 10 m apart along the fence.
- The energiser, earth and keypad, with the alarm linked to your armed response company through an isolation relay if you have one.
- The test and the hand-over. Every zone checked with a fence tester, the factory PINs changed, and the certificate given to you.
Certified electric fence installer. The process in more detail is on electric fence installation.

JVA energisers, compared
We fit and repair Nemtek energisers and JVA's Z-series, and JVA's range is a good example of how the choice works. These figures are from JVA's manual:
| Model | Output | On a 7 Ah battery, up to | Worth knowing |
|---|---|---|---|
| Z13 | 2.8 J | 12 h on high power, 14 h on low | Status lights; up to two keypads |
| Z14 | 4 J | 10 h on high power, 14 h on low | Voltage display; up to three keypads |
| Z18 | 8 J | 4.5 h on high power, 10 h on low | Extra relays; a tamper beam that disables it if the lid comes off |
| Z114 | 14 J | 4 h on high power, 10 h on low | Tamper beam |
The pattern matters in a power cut: the stronger the energiser, the sooner its battery runs down. A big energiser on a short garden wall wastes battery, and a small one on a long boundary is underpowered, so we size it to the fence. Every Z-series model has lightning protection built in on both the mains and fence sides, and JVA still advises extra protection on the fence where lightning is common. Nemtek's models are compared with these on our energiser page.

Wall-top or freestanding
A wall-top fence is the usual choice for a house: brackets on the boundary wall carry six to twelve lines above it. Where there's no wall to build on, such as an open stand, the edge of an estate or a business park behind palisade, a freestanding fence stands on its own posts with many more lines, from 18 upwards, and costs more a metre because of it. A freestanding fence can also run just inside a palisade or ClearVu-type fence, so the steel keeps people back and the electric fence raises the alarm.
Estates and business parks: energisers in a group
A long boundary is split into zones, and on a large estate or business park that can mean several energisers. JVA's Z-series energisers can be linked into a group: one master and up to fourteen others, all pulsing at the same moment so that they act as a single energiser with many outputs.
That's about safety as much as convenience. Where two fences run off energisers that pulse independently, someone touching both could be shocked by one and then by the other a fraction of a second later. So the standard JVA quotes requires at least 2.5 m between such fences, closed only with something that doesn't conduct, such as a wall. JVA's own point is that the gap is a weak spot; a synchronised group lets the fence run unbroken.
A grouped system is run from up to three keypads, which can arm or disarm every zone or just one, and each zone can carry a name, so the keypad says "back wall" rather than a number.
Your JVA keypad, day and night
JVA's manual lists the key sequences, and these are the ones a household or a guardhouse uses most:
- Arm or disarm: your user PIN, then #.
- Silence the siren: 1470# is JVA's shortcut.
- Low power by day: your PIN, then *41#; back to full power with your PIN, then *42#. JVA describes low power as keeping the fence detecting while making it safer for the public during the day.
- Bypass the gate alarm: your PIN, then *54#; switch it back on with your PIN, then *53#.
- Change your user PIN: your PIN, then *0#, then the new four-digit PIN and #.
The factory PINs are 1234 for the user and 012345 for the installer. We change the installer PIN when we hand the fence over and show you how to change your own, because anyone who knows a factory PIN can switch the fence off.

Repairs to Midrand fences
We test the fence zone by zone and repair what we find:
- Coms Fail on a grouped JVA system: it can mean the energiser on zone 1 has dropped off the group, and without it the others stop reporting to the keypad.
- A flat battery after a long outage: a JVA energiser stops working when its battery falls below 6.5 V but still draws a little current, so a long cut can leave the battery fully drained. We test it before replacing it.
- Plants and branches across the lines, and wire broken or gone slack.
- Insulators cracked by sun and age, arcing in the rain.
- Gate contacts out of line, so a shut gate reads as open.
- Energisers and keypads after lightning, repaired on the bench or replaced.
All our spare parts are genuine, and every repair comes with our six-month guarantee on our repairs. The checks that are safe for you to do are in the fault finder below; never touch the fence or open the energiser.
Selling a property with an electric fence
When a Midrand property with an electric fence is sold, the fence needs an Electric Fence System Certificate. We inspect it, issue the certificate if it passes, and price whatever stands in the way if it doesn't. More on electric fence certificates.
Typical electric fence prices
Typical market prices in Gauteng, from installer price lists, cost guides and shop listings, not ours:
- 6-line wall-top fence, installed: R95–R115 a metre (published price lists of Gauteng installers)
- 10-line wall-top fence, installed: R130–R145 a metre (published price lists of Gauteng installers)
- 18-line freestanding fence, installed: R205–R225 a metre (published price lists of Gauteng installers)
- JVA Z13 (1 zone), in shops: about R3 370 (Takealot)
- Lightning diverter unit: R350–R600 (Kandua)
- Energiser repair: R800–R2 500 (Kandua)
Prices checked October 2026. Your exact price is set in a free quote before any work starts. No call-out fee when we do the work. If no work is done, a R650 call-out fee applies.
Booking an electric fence technician in Midrand
For a new fence, give the boundary's rough length and whether it's on a wall or freestanding; for a repair, the energiser's make and what the keypad or display shows. We work across Midrand, from Halfway House, Vorna Valley and Noordwyk to Randjespark, Country View, Ebony Park and Waterfall. Same-day repairs are possible when the day's bookings allow, and a fence that has had to be switched off is treated as urgent.
Fault finder
What is your fence doing?
Pick what you're seeing for the likely causes, the safe checks you can do yourself, and when to stop and book. Taken from the manufacturers' own manuals.
What's it doing?
Likely causes
Electric fence · the alarm keeps going off
Most likely first
The fence voltage has dropped below the alarm level: something is touching the wires, or plants have grown into the fence.
The gate input is open: the gate isn't fully closed.
The fence condition is poor: dirty or failed insulators, or wet insulators after rain.
Safe checks you can do
When to stop and book
Never touch the fence wires or open the energiser. If the alarm won't clear, we'll find the fault on the fence.
From the official manuals: Nemtek Druid 25 and 28 user manual, Nemtek Druid LCD user manual.
Questions
Electric fence questions in Midrand
What are the factory PINs on a JVA energiser?
JVA's manual gives 1234 as the user PIN and 012345 as the installer PIN on its Z-series. Change them, because anyone who knows a factory PIN can switch your fence off. Read about the keypad.
How long does a JVA energiser run in load-shedding?
On a 7 Ah battery, JVA gives up to 12 hours on high power for the Z13 and 10 for the Z14, but 4.5 for the Z18 and 4 for the Z114, with longer on low power. Compare the models.
Can several energisers on our estate work as one fence?
Yes, JVA's Z-series can link up to fifteen energisers, one master and fourteen others, pulsing together as one. That also lets fences on different energisers meet without the 2.5 m gap. Read about groups.
How do I silence a JVA fence siren?
JVA's shortcut is 1470# on the keypad. If the alarm keeps returning, the fault is still on the fence, and it's worth a call. See the keypad sequences.
Book a technician
Get an electric fence quote in Midrand
Job card
We WhatsApp or call you back. Fields marked (required) are needed.