Guides · Intercoms
GSM intercom not working: when the gate stops calling your phone
A GSM intercom is really a cellphone in a box at the gate: it has a SIM card, needs airtime and signal, and calls the numbers stored in it when a visitor presses the button. So when it stops working, the cause is very often the same thing that stops a phone working: no airtime, no signal, or a SIM that's been blocked or swapped. Here's how to work through it, using Centurion's G-SPEAK as the example.
Six-month guarantee on our repairs

What exactly isn't working?
| Symptom | Usual cause |
|---|---|
| Pressing the button does nothing, no call | No airtime, no signal, or no power at the gate station |
| It used to call, stopped suddenly | Airtime or a bundle ran out, or the SIM was blocked or expired |
| It calls the wrong phone, or not your new one | The stored numbers weren't updated |
| The call connects but breaks up | Weak signal or the antenna |
| You can talk, but the gate won't open | The keypad tones from your phone, or the link to the gate motor |
| Nothing at all after a storm | A surge to the unit or its power supply |
1. The SIM and the airtime
This is the cause more often than anything else. The gate station needs a working SIM with airtime on it, just like a phone. Centurion's G-SPEAK manual calls for a network- and RICA-registered SIM with airtime loaded.
Things that quietly stop it:
- Airtime has run out, or a bundle expired at the end of the month.
- The SIM was a prepaid one that expired after a long period without being topped up.
- The SIM was replaced or the number was ported, and the new one wasn't set up.
- A SIM PIN was switched on, so the unit can't use the SIM after a restart.
Centurion's G-SPEAK ULTRA shows the SIM's phone number, its airtime balance and its call and SMS credits on its own screen, which makes the first check quick. On older units, top up the SIM and test.
2. The signal
A gate station at the end of a long driveway, behind a wall or in a metal pillar can sit in a weak-signal spot. Signs: calls that drop, break up or don't connect at certain times.
- Check the signal reading on the unit: the original G-SPEAK shows signal strength on LEDs by its antenna; the G-SPEAK ULTRA shows it on its screen.
- Check the network. The original G-SPEAK works on 2G GSM; the ULTRA uses 4G with 2G as a fallback. A unit that relies on a network that's weak or changing in your area will struggle.
- Consider the antenna. The ULTRA uses an internal antenna by default, with an external one that can be connected and mounted where the signal is better. Centurion also mentions moving the antenna to cure interference.

3. The numbers it calls
Each call button rings the numbers stored for it. On a G-SPEAK ULTRA, each button can have a primary and a secondary number. When a phone number changes, a family member leaves, or a new tenant moves in, the stored numbers have to be changed too, or the intercom carries on calling the old phone. If the intercom rings someone, just not you, this is almost certainly why. Numbers are changed through the unit's setup, which on the ULTRA is done through Centurion's G-WEB platform.
4. It calls, but the gate won't open
On most GSM intercoms, you open the gate from the call by pressing a key on your phone, which sends a keypad tone (DTMF) down the line to the unit. If that doesn't work:
- Press the key firmly and once, while the call is connected.
- Check your phone sends keypad tones during calls; some phones or headsets interfere.
- Test the gate with a remote. If the remote doesn't open it either, the gate motor is the problem; see gate motor not working.
- If the remote works, the link from the intercom's output to the gate motor's trigger input needs checking. See intercom not opening gate.
5. Power and storms
The gate station needs power from the gate motor or its own supply. A unit that's completely dark has lost its power, or been damaged by a surge along the cables. After a lightning storm, check whether the gate motor and the fence also failed: if several things died together, a surge is the likely cause. When a G-SPEAK unit first starts on the network, the original model gives three short beeps once it has registered; if you hear nothing after power returns, it hasn't.
Safe checks you can do
- Check the airtime on the SIM, from the unit's screen or by calling the SIM's number.
- Top up if needed, and wait a few minutes before testing.
- Look at the signal reading on the unit.
- Ask who the intercom is calling: if it rings someone else, the numbers need updating.
- Test the gate with a remote to rule the motor in or out.
Don't open the unit or swap the SIM yourself on a unit that uses a PIN or e-SIM: setup changes on a GSM intercom are made through its programming, and a wrong change can lock out every user.
When to call us
Call us when the SIM has airtime and signal and it still won't call, the numbers need changing and you don't have the setup details, the gate won't open from the call with remotes working, or the unit died after a storm. We set up and repair GSM intercoms and GSM gate openers, move antennas, and wire them to the gate motor. All our spare parts are genuine, and every repair carries our six-month guarantee on our repairs. No call-out fee when we do the work. If no work is done, a R650 call-out fee applies. More on how they work is on GSM intercoms.
Questions
Questions about GSM intercoms
Why does my GSM intercom no longer ring my cellphone?
Most often the SIM has run out of airtime or expired, or the signal at the gate is too weak; if it rings someone else, the stored numbers haven't been updated. Check the airtime first. See the SIM and airtime.
Does the SIM card in a GSM intercom need airtime?
Yes: it makes ordinary calls from its own SIM, so it needs a registered SIM with airtime, and Centurion's G-SPEAK manual says so. The G-SPEAK ULTRA shows the balance on its screen. See the SIM and airtime.
Why can't I open my gate from the GSM intercom call?
The gate opens from a keypad tone sent by your phone during the call, so press the key firmly once while connected; if a remote also fails, the motor is at fault, and if the remote works, the link to the motor needs checking. See opening the gate.
Book a technician
Get an intercom quote
Job card
We WhatsApp or call you back. Fields marked (required) are needed.