Skip to content

24/7 emergency repairs across Gauteng

081 566 5451

Guides · Intercoms

Intercom not opening the gate: when it rings but nothing moves

The intercom rings, you can hear the visitor and they can hear you, but when you press the button to let them in, nothing happens. That's actually good news: the intercom's calling side is fine. The fault is somewhere in the short chain from the release button to the gate motor, and it can usually be narrowed down in a few minutes. Here's how.

Our promise

Six-month guarantee on our repairs

Emergency

24/7 emergency repairs across Gauteng

A technician wiring the back of a gate intercom keypad on a steel pedestal at a driveway

How the intercom opens the gate

When you press the release button on the handset or the screen, the intercom closes a set of contacts, a relay, for a moment. Those contacts are wired to the gate motor's trigger input, the same input a wall button would use, and the motor treats the pulse like a remote press. On Zartek's ZA-660-A, for example, the gate station has a relay that triggers a motorised gate or a striker lock; Centurion's G-SPEAK ULTRA wires to the trigger inputs on D-series and V-series controllers.

So there are four links in the chain: the button on the handset, the relay in the intercom, the wire to the motor, and the motor accepting the trigger. Any one can break.

A technician wiring the back of a gate intercom keypad on a steel pedestal at a driveway

The first test: does the remote open it?

Press a gate remote. What happens tells you which half of the chain to look at:

  • The remote doesn't open the gate either: the problem is the gate motor, not the intercom. See gate motor not working.
  • The motor beeps five times and nothing moves: on ET's Drive motors, that's holiday lock-out, which blocks every trigger, the intercom included. It's switched off with the same remote presses that switched it on.
  • The remote opens the gate normally: the motor is fine and accepting triggers, so the fault is in the intercom's release, its relay or the wire between them.

When the motor is the reason

Even with remotes working, a motor can ignore the intercom for reasons of its own:

  • The release is open. A motor left on manual won't run for anything; ET's Drive cards show rel.
  • A mode that only accepts certain triggers. Some motors have modes, such as ET's condominium mode, where an open gate ignores further presses until it auto-closes. If the gate is already open, the intercom may seem to do nothing.
  • The intercom is wired to the pedestrian input, so the gate opens only a little, or the wrong input after a motor was replaced.
  • A new motor or control card, fitted without moving the intercom's wires to the matching terminals.

When the intercom is the reason

If remotes work and the motor isn't in a lock-out, the release side of the intercom is next:

  • The button. Try the release button on every handset or screen you have. If one opens the gate and another doesn't, that handset's button or its link is the fault.
  • Lock A or Lock B. Some systems have two releases. On a Zartek CDP-808, Lock A opens the main gate and Lock B closes a separate contact for a second gate or door, and the screen shows which one opened. Pressing the wrong one does nothing at the gate.
  • The relay. A relay that clicks but doesn't switch, or doesn't click at all, needs replacing.
  • The wire. A cable cut by digging, chewed, or damaged by a surge after a storm, between the intercom and the motor.
  • Power at the gate station, where the release runs from it: Zartek's ZA-660-A gate station runs from its own supply or the gate motor's 12 V, with AAA batteries only as a short backup.

Pedestrian gates and striker locks

If the intercom is meant to open a pedestrian gate with a striker or magnetic lock, rather than the driveway motor, the lock and its power supply are part of the chain. A striker lock that hums but doesn't release is usually low on power or binding against its keeper; a gate that's dropped on its hinges presses on the lock so it can't spring open. Zartek's ZA654 manual notes that if an electric latch on its terminals doesn't work, reversing the 12 V polarity is worth trying, which is an installer's job. More on intercom systems for complexes where doors and locks are common.

Safe checks you can do

  1. Test with a remote, as above.
  2. Try every handset and button, and both Lock A and Lock B if you have them.
  3. Check the motor isn't on manual or in holiday lock-out.
  4. If you have an entry code on the gate station, try it: on a Zartek CDP-808, a resident's code opens Lock A directly. If the code works but the handset doesn't, the handset or its link is at fault.
  5. Note what you hear: a click from the intercom or the motor when you press release, or nothing.

Don't open the intercom or the gate motor to look at the wiring: both can carry mains, and the motor's battery can deliver a dangerous current.

When to call us

Call us when remotes work but no handset opens the gate, when only one handset fails, when a striker lock won't release, or since a motor or intercom was replaced. We trace the release from the button to the motor, replace relays, cables and handsets, and rewire to the right input. All our spare parts are genuine, and every repair carries our six-month guarantee on our repairs. No call-out fee when we do the work. If no work is done, a R650 call-out fee applies. Other intercom faults are on intercom not working.

Questions

Questions about intercoms that won't open the gate

Why won't my gate open from the intercom when the remote works?

The motor is fine, so the fault is in the intercom's release: the button on that handset, the relay that switches, or the wire to the motor's trigger input. Try every handset and both release buttons first. See the intercom side.

Why does my gate motor beep five times when I press the intercom?

On ET's Drive motors, five beeps and no movement means holiday lock-out is on, which blocks every trigger including the intercom. Switch it off with the same remote presses that set it. See the remote test.

Why does my intercom open the gate only a little?

It's probably wired to the motor's pedestrian input, which opens just wide enough for a person; a technician can move it to the full-opening input. See the motor side.

Book a technician

Get an intercom quote

Job card

We WhatsApp or call you back. Fields marked (required) are needed.

Property type
When
Photos (optional, up to 4)

No call-out fee when we do the work. If no work is done, a R650 call-out fee applies.